Requirements for the amount of ventilation and the size of the opening can be found in Chapter 806, Roof Ventilation, of Chapter 8, Construction of Roof Ceilings. The following requirements come directly from the IRC: The minimum area of net ventilation must be equal to 1/150 of the surface of the ventilated room. Are there different roof ventilation requirements for different climate zones? Washington State, where I live, is very wet and humid. I thought I had ventilated the roof well a few months ago when we made our roof, but today I see small drops of water under the terrace plywood on the roof and mold growth. Often, static drains are installed on a roof that also has ridge ventilation. This follows the belief “the more, the better” or that you can never have too much ventilation. However, this design should be avoided because static exhaust vents create a “short circuit” of the intended airflow. See Figure 6. Figure 6 – Example of a short circuit in the static ventilation system. Image courtesy of NRCA. Are you sure about your mechanical ventilation plan? People don`t shower in the attic. One of the simplest and most effective ways of ventilation on a roof is to use ridge ventilation. Ridge ventilation is installed at the top of the roof, where warm air rises.

To install ridge ventilation, a certified roofer cuts the roof covering to create an opening for the attic. The ventilation of the ridge is installed on the tip with nails and clad for aesthetic reasons. Ridge ventilation is one of the easiest ways to meet roof ventilation requirements. Other options to meet your attic ventilation needs include: standard attic vents such as AF-50, ventilation fans, or solar-powered attic fans. Attic ventilation serves an important purpose and is the key to a well-functioning roofing system. Anyone who deals with residential roofs should become familiar with the purpose of attic ventilation and understand how to achieve an effective ventilation system while meeting the requirements of building codes. A notable finding of this “exception” is that it is acceptable to have up to 10% of more than 50% of the ventilation area at the intake level. In addition, it can be interpreted that it is not desirable to have more than 50% ventilation surface on the exhaust plane. The intake area must always be equal to or greater than the exhaust surface, otherwise intake air may pass through openings in the ceiling (e.g.

lights, attic doors) may be drawn from inside the building/apartment. Attic ventilation is often considered a technical requirement for pitched roofs as well as a requirement of construction law. However, since the 2009 edition of the IRC, attics can be designed to be ventilated or not. Thus, the decision to ventilate an attic is not dictated by building codes. It`s really a design decision. For the purposes of this article, only the 2018 edition of the International Residential Code (IRC) is discussed. Most attic ventilation requirements have not changed significantly from previous editions. Although the primary code requirement is the 1:150 ratio, a 1:300 ratio is often used. To use 1:300, you must meet both conditions of the exception.

The first condition requires a Class I or II vapour retardant for buildings in climates 6 to 8. An example of a Class I steam retarder would be a polyethylene sheet that should be installed on the warm side of attic insulation. A Class II vapour retardant could be electrically coated fiberglass slat insulation installed in the attic with kraft paper side down. In the past, roof ventilation and attic ventilation were not so critical because moisture escaped from old windows, doors and even through walls. With modern building codes and building materials such as vapour barriers, vinyl siding and high-tech windows, very little moisture enters or leaves the home. As mentioned earlier, intake and exhaust vents are necessary for the ventilation system to be effective. You can`t have one without the other. Soffit openings should be checked to confirm that this is not the case: closed attics and closed rafters, where the ceilings are attached directly to the underside of the rafters, must have cross ventilation for each individual room through ventilated openings protected from rain or snow. Vents must be at least 1/16 inch (1.6 mm) and no more than 6.4 mm (1/4 inch). Vents with a minimum size of 1/4 inch (6.4 mm) must be equipped with corrosion-resistant wire mesh, hardware, perforated vinyl or similar material with openings of at least 1/16 inch (1.6 mm) and not more than 1/4 inch (6.4 mm).

Openings in structural elements must comply with the requirements of clause R802.7. The necessary vents must open directly to the outside air and be protected to prevent the entry of birds, rodents, snakes and other similar creatures. Attic ventilation performs two main functions: lowering the temperature of the attic and removing excess moisture. Lowering the temperature in the attic can help reduce air conditioning and roof terrace temperature energy costs, optimize the life of a roof, and minimize the ice dam. Some benefits of removing excess moisture include reducing the possibility of mold and mold growth and minimizing the risk of wood rot. According to the National Roofing Contractors Association (NRCA), a vent with an air flow of 1.0 cubic feet per square foot of attic, measured in the attic, is generally considered equivalent to a ventilation ratio of 1:150. Every 3 years, the International Residential Building Code (IRC) publishes code updates. 2018 is a cycle year. Underneath is the ventilation section of the attic. Important notes/changes: Good contribution to ventilation. It is annoying to walk past houses and visually see poorly ventilated houses. Many may not be aware that ventilation of attic houses was a requirement in the very first edition of the Building Officials Conference of America`s (BOCA) Model Building Code, published in 1948.

And, of course, attic ventilation is still dealt with today in model building regulations. But considering that attic ventilation has been required for over 70 years, it remains one of the most misunderstood concepts in the roofing industry. As a result, many attics are not properly ventilated. Daily activities in your home such as showering, rinsing water, washing clothes, or turning on the oven create heat and moisture in the air. This moisture is sucked into the attic by driven exhaust fans. If the attic does not have a proper roof ventilation system, moisture remains in the attic and begins to wreak invisible havoc. To better understand attic ventilation, it is best to start with the basics. In this article, you`ll learn why you need ventilation, the most common type of ventilation, building code requirements, and common ventilation issues. Outside air enters the attic through soffit or eaves openings, rises through the attic as it warms up, and exits through vents at or near the top.

For this method to be most effective, approximately equal amounts of ventilation must be placed at the height of the soffit or eaves and on or near the top of the attic. This is called a “balanced system.” See Figure 1. To find the right attic ventilation solution for your roofing project, choose from a full range of ridge and hip vents, electric and solar vents, roof and gable tiles, wind turbines, inlet openings and much more from GAF.