By law, fire doors must be installed at least along the designated escape route in accordance with the Regulatory Reform (Fire Safety) Ordinance 2005 (RRO). These regulations require owners to install appropriate fire doors in all commercial premises in the UK and designate a responsible person to ensure regular inspections of fire doors under the direction of the RRO. The regulation also requires responsible persons to provide information on the importance of fire doors for the fire protection of a building to the occupants of all multi-dwelling residential buildings with two or more sets of living spaces (which have common areas). The spaces on the sides and top of the fire door shall have a maximum width of four millimetres. Prior to the Fire Protection Act 2021, flat entrance doors in multi-unit residential buildings may not have been systematically considered as part of the fire risk assessment process. The Fire Protection Act 2021 removed legal ambiguity and confirmed that flat entrance doors fall within the scope of the Fire Protection Ordinance. New buildings are subject to the standards set out in the approved building by-law documents. These are designed to ensure that all new buildings in the UK meet minimum building standards. Fire doors are mandatory in all commercial or public buildings and the requirements are listed in the following approved documents: If a fire door is installed and used correctly, it can help limit the spread of fires in buildings and give residents the opportunity to leave the structure, and firefighters to go to the scene of the crime and fight the fire and even save the building.

The minimum requirement is that the person in charge conduct a door inspection to identify obvious damage or problems. It should not be necessary to appoint a specialist for those checks, as the person responsible should be able to carry out those checks himself. There are several useful guides available online that can help a responsible person conduct exams. The Fire Safety (England) Regulations 2022 make this a legal requirement for those responsible for all multi-inhabited residential buildings in England with floors over 11 metres in height from 23 January 2023: There are several regulations in the UK that are connected to fire doors. This article provides a breakdown of each item and associated items. There are also laws regarding fire safety in any property classified as non-apartment. The elements and buildings covered in this document include: By stating that fire doors must provide the same level of fire protection as solid building components, British Standard 8214 deals with the maintenance, installation and specification of fire doors. According to the Fire Protection Ordinance 2005, this road must be lined with at least fire doors. The environment, location and building type of the door are considered in an independent assessment that is used to determine the most appropriate FD rating of the fire doors to be installed.

In addition, the study (recommendation 33.30) recommended that all persons responsible for the condition of entrance doors to individual apartments in high-rise residential buildings (with hazardous cladding) be required by law to ensure that these doors comply with applicable standards [footnote 2]. At all levels, each stairwell door must be a fire door that leads to a safe space in residential buildings with more than two levels. In addition, in a mixed-use building, fire doors are required between residential and commercial premises; and between the integral garage and the house in roof extensions. In the event of a fire, the fire doors must divide the building into separate compartments. In this way, residents have a protected way out of the building or room for the time indicated by the FD assessment of the doors. On the other hand, there are external fire doors at the end of the exit path; and therefore do not have to remain closed or even be fire resistant. The fire door required in your building is determined by the fire risk assessment. The “responsible person” should ensure that an up-to-date fire risk assessment has been completed. Fire risk assessments are a thorough examination of the site. They highlight all fire hazards and make recommendations to reduce or eliminate these risks.

This includes where fire doors should be used and how popular they should be. Given these statistics, it is strongly recommended that anyone responsible for managing the fire protection of a residential building work closely with a fire protection company to ensure that fire doors are installed correctly and regularly maintained to the highest standards, as recommended in BS 8214. If problems are detected during these inspections, it may be appropriate to perform more detailed inspections of the doors (or self-closing device) if damage is detected during the initial inspection. This could involve hiring a specialist. The FD rating given to fire doors depends on how long they can withstand fire. To put this in perspective, fire doors that offer 60 minutes and 30 minutes of protection have an FD60 and FD30 rating. FD ratings are issued after stress tests in accordance with the guidelines of BS 476 Part 22: 1987. To ensure that fire doors are fully functional when they are to be used, they require regular maintenance and inspection. In general, inspections should be carried out twice a year, with more checks required for doors that are considered susceptible to damage due to regular use in busy areas. Preferably, these inspections should be carried out by an inspector registered with the FDIS.

The knowledge and skills of these inspectors were independently assessed as they obtained a diploma in fire doors. The law does not mention specific accreditation or qualification requirements for those involved in the installation of fire doors. However, it is important that this company is left in the hands of an experienced and respected expert, because the slightest problem, whether it is a crack or a gap between the seal, glassware or door and frame, can lead to a faulty fire door that does not meet the safety requirements set out in the RRO.